Closed Type Cooling Tower
Home » Products » Cooling Tower » Seawater Cooling Tower » Closed Type Cooling Tower
Closed Type Cooling Tower Closed Type Cooling Tower

loading

Closed Type Cooling Tower

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
sharethis sharing button
The complete set of closed cooling tower equipment is composed of main engine, water tank, circulating water pump and electric control cabinet. The main engine is composed of shell, heat exchanger, fan, spray water pump, water collector, water tank, pipeline valve and other parts.
Availability:
Quantity:

The complete set of closed cooling tower equipment is composed of main engine, water tank, circulating water pump and electric control cabinet. The main engine is composed of shell, heat exchanger, fan, spray water pump, water collector, water tank, pipeline valve and other parts.


During operation, the cooling medium (soft water, oil or other liquids) is driven by the main circulating pump to circulate between the heat exchanger and the equipment to be cooled. The spray water is evenly sprayed on the heat exchanger to form a uniform water film on the outer surface of the heat exchanger. The cold air enters the tower from the air inlet below the tower and flows counter to the spray water through the surface of the heat exchanger, In this process, there are two heat exchange modes, namely, the heat conduction between cold air and cooling medium and the heat exchange of evaporation and heat absorption of spray water. The saturated hot and wet air after absorbing heat is discharged to the atmosphere by fan, and the rest of the spray water flows into the water tank at the lower part of the tower and then transmitted to the spray system by water pump. In this way, the cooling medium in the heat exchanger is cooled.


Advantage:

1. The fully closed circulation of cooling medium can prevent sundries from entering the cooling pipeline system and evaporation loss of cooling medium.

2. Soft water is used as cooling medium, without scaling, blocking pipeline and less faults.

3. The double cooling mode of air cooling and spray water evaporation and heat absorption is adopted, with high cooling efficiency.

4. The device has the advantages of small volume, small occupied space, convenient movement and placement, and there is no need to build a pool.

5. Automatic intelligent control is adopted, which can automatically change the cooling mode according to the working conditions, and the operation is simple and reliable.

6. It is widely used. It can directly cool quenchant, oil, alcohol and other media without corrosion to heat exchanger. The media has no loss and stable composition.


Previous: 
Next: 

Contact Us

 lukeliu@czct-coolingtower.com
     cindyxu@czct-coolingtower.com
  +86 13582648620
  +86-22-25380628
  +86-13389955839
  369446883@qq.com
Copyright@2022 China Chemical Engineering Cangzhou Cooling Technologies Co., Ltd.Supported by Leadong.Sitemap